3. K17 accessory list, power supply instructions

[Instruction of the operating power supply for K17]

The K17 utilizes a 35W linear power supply with a universal AC connector.

When using the K17 for the first time, please make sure that the voltage switch at the bottom matches the local voltage [230V or 110V].

 

[Fuse Parameters]

250V/500mAH 5.2x20mm

 

[Function of the grounding post in the rear panel]

1.When K17 is paired with other device which cannot be connected to the power ground, it can be connected through the grounding post.

2.You can connect the metal shell of K17 directly to the earth through the grounding post, which can enhance the anti-static capability of the equipment.

3.Improve the ground loop, potentially to improve loop interference

 

[Trigger design specifications and recommended cables]

Trigger IN: Nominal 12V trigger, which can be triggered via 5-15V. The power consumption is lower than 20mA;

It is recommended to use a 2pins 3.5mm cables or a 3pins 3.5mm cables (in practice, the L and GND pins are used for the positive/negative signals, and the R pin is not connected.)

 

[Remote control instructions]

 

[Difference between powering off via panel knob and entering standby mode via remote control]

1.When powering off via the panel knob, there will be boot animation after restart.

2.When entering standby mode via remote control standby, no boot animation when you turn it on again and you can wake up the K17 immediately.

 

Views:0
Collection